Extensive Product StockNationwide DeliveryFree Office Pickup
Shop by categorySee all →
Solar PanelsSolar InvertersLithium BatteriesHome IPSSolar PackagesDiesel Generators
Buying guide

Diesel Generator Price in Bangladesh 2026: Cummins, Perkins and Ricardo by kVA

ডিজেল জেনারেটরের দাম ২০২৬: কেভিএ ও ব্র্যান্ড অনুযায়ী

By GPTECH Team 14 min read

Quick answer

Diesel generator prices in Bangladesh run from about ৳3.3 lakh for a 20kVA canopy set to over ৳80 lakh for 650kVA. Price depends mostly on engine brand (Ricardo, Cummins, Perkins) and size; size by your load and largest motor.

Diesel generator price in Bangladesh 2026 guide banner

Diesel generator price in Bangladesh 2026 guide banner

The diesel generator price in Bangladesh ranges from about ৳363,000 for a 20kVA canopy set to well over ৳80 lakh for a 650kVA industrial set. Brand matters as much as size: a 30kVA Ricardo with canopy is ৳396,000, the same size with a Cummins engine is ৳825,000, and with a Perkins engine it is ৳1,155,000.

That spread confuses a lot of buyers. In this guide we lay out current prices for every brand and size we sell, explain what you get for the extra money, and show how to size a generator properly so you do not pay for capacity you will never use or, worse, buy one that cannot start your largest motor. Prices in the tables come live from our shop and match our latest supplier price list.

Cummins 150kVA diesel generator with canopy price in Bangladesh
A Cummins 150kVA diesel generator with soundproof canopy, a common size for apartment buildings and mid-size factories.

Diesel generator price in Bangladesh: quick guide

Size Budget option Mid-range option Premium option
30kVA Ricardo, ৳396,000 EVOL, ৳764,500 / Cummins, ৳825,000 Perkins, ৳1,155,000
60kVA Ricardo 62.5kVA, ৳528,000 EVOL, ৳984,500 / Cummins, ৳984,500 Perkins, ৳1,424,500
100kVA Ricardo, ৳742,500 EVOL, ৳1,199,000 / Cummins, ৳1,243,000 Perkins, ৳1,908,500
150kVA Ricardo, ৳907,500 EVOL, ৳1,518,000 / Cummins, ৳1,595,000 Perkins, ৳2,472,800
200kVA Ricardo, ৳1,237,500 Lambert (open), ৳1,408,000 / Cummins (open), ৳2,227,500 Perkins (open), ৳2,629,000

All prices above are for the generator only; the automatic transfer switch (ATS), installation and fuel are extra. You can browse every model on our diesel generators page.

Why the same kVA costs so differently

The engine is most of the cost. Generators with Ricardo and similar Chinese-built engines are the most affordable and suit standby use where the set runs a few hours a week. Cummins-engine sets assembled in China sit in the middle and are widely trusted for regular use. Perkins engines, designed in the UK, carry the highest price and are often chosen for hospitals, data rooms and sites where the generator runs for long hours. The alternator, controller and canopy quality also differ between price levels.

Ricardo generator price list (with canopy)

Ricardo-engine sets are the most popular choice for apartment buildings, small factories, markets and offices that need reliable standby power without a premium price. All of these come with a soundproof canopy and a DC52D controller.

Model Rating Price
Ricardo EPS-HC20 20kVA / 16kW ৳363,000
Ricardo EPS-HC30 30kVA / 24kW ৳396,000
Ricardo EPS-HC40 40kVA / 32kW ৳418,000
Ricardo EPS-HC50 50kVA / 40kW ৳462,000
Ricardo EPS-HC62.5 62.5kVA / 50kW ৳528,000
Ricardo EPS-HC80 80kVA / 64kW ৳715,000
Ricardo EPS-HC100 100kVA / 80kW ৳742,500
Ricardo EPS-HC125 125kVA / 100kW ৳797,500
Ricardo EPS-HC150 150kVA / 120kW ৳907,500
Ricardo EPS-HC200 200kVA / 160kW ৳1,237,500
Ricardo KOFO EP-KF200 (open set) 200kVA / 160kW ৳1,045,000

Cummins generator price list

Cummins-engine generators are a step up in durability and are a common choice for factories, hotels and commercial buildings where the set runs regularly. Small sizes come with a canopy; larger sizes are usually supplied as open sets for installation in a generator room.

Model Rating Type Price
Cummins EPS-CU30 30kVA / 24kW Canopy ৳825,000
Cummins EPS-CU40 40kVA / 32kW Canopy ৳874,500
Cummins EPS-CU50 50kVA / 40kW Canopy ৳935,000
Cummins EPS-CU60 60kVA / 48kW Canopy ৳984,500
Cummins EPS-CU80 80kVA / 64kW Canopy ৳1,155,000
Cummins EPS-CU100 100kVA / 80kW Canopy ৳1,243,000
Cummins EPS-CU150 150kVA / 120kW Canopy ৳1,595,000
Cummins EPS-CU150 150kVA / 120kW Open set ৳1,419,000
Cummins EPS-CU200 200kVA / 160kW Open set ৳2,227,500
Cummins EPS-CU250 250kVA Open set ৳2,475,000
Cummins EPS-CU300 300kVA / 240kW Open set ৳2,530,000
Cummins EPS-CU350 350kVA / 280kW Open set ৳3,806,000
Cummins EPS-CU500 500kVA / 400kW Open set ৳4,510,000
Cummins EPS-CU650 650kVA / 520kW Open set ৳8,371,000
Cummins 200kVA open type diesel generator for factories
A Cummins 200kVA open set. Open sets are installed in a ventilated generator room.

Perkins generator price list (GTS)

Perkins-engine generators assembled by GTS are the premium choice in our range. Buyers pick them for critical loads and for sites that need the generator to run for long periods, such as hospitals, cold storage and continuous-process factories.

Model Rating Type Price
Perkins PS30 30kVA / 24kW Canopy ৳1,155,000
Perkins PS45 45kVA / 36kW Canopy ৳1,292,500
Perkins PS60 60kVA / 48kW Canopy ৳1,424,500
Perkins PS80 80kVA / 64kW Canopy ৳1,639,000
Perkins PS100 100kVA / 80kW Canopy ৳1,908,500
Perkins PS150 150kVA / 120kW Canopy ৳2,472,800
Perkins PS150 150kVA / 120kW Open set ৳2,282,500
Perkins PS200 200kVA / 160kW Open set ৳2,629,000
Perkins PS250 250kVA / 200kW Open set ৳3,685,000
Perkins PS350 350kVA / 280kW Open set ৳5,005,000
Perkins PS500 500kVA / 400kW Open set ৳7,029,000
Perkins PS650 650kVA / 520kW Open set ৳9,152,000

EVOL and Lambert generator prices

EVOL canopy sets offer a middle path between Ricardo and Cummins on price, and Lambert open sets are a value option for larger standby installations.

Model Rating Type Price
EVOL EV30 30kVA / 24kW Canopy ৳764,500
EVOL EV45 45kVA / 36kW Canopy ৳874,500
EVOL EV60 60kVA / 48kW Canopy ৳984,500
EVOL EV80 80kVA / 64kW Canopy ৳1,045,000
EVOL EV100 100kVA / 80kW Canopy ৳1,199,000
EVOL EV150 150kVA / 120kW Canopy ৳1,518,000
Lambert EP-LM200 200kVA / 160kW Open set ৳1,408,000
Lambert EP-LM250 250kVA Open set ৳1,595,000
Lambert EP-LM300 300kVA Open set ৳1,787,500
Lambert EP-LM350 350kVA / 280kW Open set ৳2,200,000
Lambert EP-LM500 500kVA / 400kW Open set ৳2,585,000

kVA, kW and how to size a generator

Generators are sold in kVA, but your equipment uses kW. For diesel generators the standard conversion is kW = kVA × 0.8. So a 100kVA generator can deliver about 80kW of real power. That 0.8 is the power factor the generator is designed for; inductive loads such as motors and older lighting pull the real-world figure around.

To size a generator properly:

  1. List the loads you want on backup and their running power in kW: lifts, water pumps, lights, fans, air conditioners, machines.
  2. Find the largest motor and note that it can draw three to six times its running current while starting. A lift motor or a large pump often decides the generator size more than the total load does.
  3. Add a margin. Diesel generators are happiest running at 60 to 80 percent of their rating. A set running near full load all the time wears faster; one running at very light load suffers from “wet stacking”, where unburnt fuel builds up in the exhaust.
  4. Divide your total kW by 0.8 to get the kVA, then choose the next size up that leaves that margin.

For example, a six-storey apartment building with one lift (11kW motor), two water pumps (3.7kW each), and common lighting and fans of about 8kW has a running load of roughly 26kW. The lift start-up is the critical figure, so we would usually recommend a 50kVA set here rather than a 40kVA one. Our detailed guide to diesel generator sizing in kVA vs kW includes more worked examples, and the Wikipedia article on diesel generators covers the engineering background.

Open set or canopy: which do you need?

A canopy generator comes in a weatherproof, sound-reducing steel enclosure. It can sit outdoors, in a parking area or on a rooftop, and is much quieter, which matters in residential areas and next to offices. Most sets up to about 150kVA are bought with a canopy.

An open set has no enclosure. It costs less and is easier to service, but it must be installed in a dedicated generator room with proper ventilation, an exhaust pipe led outside, a fuel tank and sound treatment if neighbours are close. Large factories and commercial buildings usually choose open sets because they already have a generator room.

You can see the price difference directly in our range: the Cummins 150kVA with canopy is ৳1,595,000, while the open set is ৳1,419,000. Remember that the generator room itself also costs money to build properly.

Perkins 150kVA diesel generator with canopy
A Perkins 150kVA canopy set. The enclosure cuts noise and lets the generator sit outdoors.

What an ATS does and what it costs

An automatic transfer switch (ATS) watches the grid supply. When power fails, it signals the generator to start and switches the building’s load across once the generator is running steadily. When the grid returns, it switches back and lets the generator cool down before stopping.

Without an ATS, someone has to start the generator and throw a changeover switch by hand every time the power goes, which means delays, and mistakes that can damage equipment. For apartment buildings, clinics and factories we recommend an ATS in almost every case. On our current supplier price list, an ATS for a 20 to 40kVA set costs about ৳20,000, rising with the generator size to about ৳1,00,000 for a 200kVA set and more for larger sets. We quote the exact ATS with each generator.

Running cost: how much diesel does a generator use?

Fuel is the biggest running cost. A modern diesel generator uses very roughly 0.25 to 0.3 litres of diesel for every kWh it produces at a healthy load. That gives approximate figures like these at 75 percent load:

Generator Load at 75% Approximate diesel use
30kVA 18kW 5–6 litres per hour
62.5kVA 37kW 10–11 litres per hour
100kVA 60kW 16–18 litres per hour
200kVA 120kW 30–35 litres per hour

These are planning figures only. Real consumption depends on the engine, load and condition; the engine datasheet gives exact numbers. Multiply the litres per hour by the current diesel price and your expected hours of load-shedding to estimate the monthly fuel bill. That figure is often what leads factory owners to look at solar for daytime loads.

Maintenance: keeping a generator ready

A standby generator that has not been looked after often fails at exactly the moment you need it. A simple routine prevents most problems:

  • Run it weekly for 15 to 30 minutes, ideally with some load, so the engine stays lubricated and the battery stays charged.
  • Check oil, coolant and fuel levels before each run.
  • Change engine oil and filters at the intervals in the engine manual, commonly every 250 running hours or once a year, whichever comes first.
  • Clean or replace the air filter more often in dusty areas.
  • Look after the starter battery. A flat battery is the most common reason a standby generator will not start.
  • Drain water from the fuel tank and keep diesel clean. Old or dirty fuel blocks injectors.
  • Book a full service with a qualified technician at least once a year.

Where to install the generator

A generator that is the right size can still cause trouble if it sits in the wrong place. Before delivery, plan these points with your installer:

  • Air. Engines need a lot of fresh air for combustion and cooling. Open sets in a room need large inlet and outlet openings; canopy sets need clear space around the enclosure so hot air does not loop back in.
  • Exhaust. Diesel exhaust contains carbon monoxide. It must be led away from windows, staircases and air intakes, never into a closed parking area where people walk.
  • Noise and vibration. Even a canopy set is audible. Place it away from bedrooms and neighbours’ windows, and mount it on a proper concrete base with anti-vibration pads.
  • Fuel. Larger installations often add an external day tank. Keep fuel storage away from heat sources and follow fire safety rules.
  • Service access. Leave room on all sides to open doors, change filters and, one day, lift out major parts.
  • Cable route. The cable run from generator to ATS and main panel should be as short as practical and sized for the full current.

For buildings in Dhaka, check with your building management or local authority whether any approvals are needed for a rooftop or ground-floor generator, especially in residential areas.

New or reconditioned generator?

Reconditioned generators are sold widely in Bangladesh, sometimes at a fraction of the new price. They can work, but the risks are real: unknown running hours, worn engine parts, rewound alternators and no warranty worth the name. If a reconditioned set fails during a long outage, the saving disappears quickly.

A new generator comes with a known engine and alternator, a manufacturer’s warranty and a clear service history from day one. For apartment buildings, clinics and factories where downtime is costly, we recommend new sets. If budget is tight, a new Ricardo-engine set is usually a better choice than a reconditioned premium brand of uncertain history.

Generator or solar plus battery?

For heavy loads such as lifts, large pumps and machinery, a diesel generator remains the practical backup. For homes, offices and the daytime load of factories, solar is now a serious alternative or companion. A solar system runs on free sunshine every day and lowers the electricity bill even when the grid is on, while a generator only costs money each time it runs.

Many of our commercial clients now use both: rooftop solar to cut daytime bills and generator run hours, and a generator for night-time and emergency backup. If that interests you, read our guide to rooftop solar for factories with three-phase on-grid systems.

Generator buying checklist

  • Has someone calculated your load, including the starting current of the largest motor?
  • Is the quoted price for open set or canopy, and does it include the ATS?
  • What engine, alternator and controller models are fitted? Ask for the datasheet.
  • Where will the generator sit, and is there space for ventilation, exhaust and service access?
  • What is included in installation: cabling, earthing, foundation, exhaust and fuel line?
  • What is the warranty on the engine and alternator, and who provides service locally?
  • Are spare parts such as filters easily available for this engine?

Frequently asked questions

What is the price of a 30kVA generator in Bangladesh?

In our range a 30kVA canopy generator costs ৳396,000 with a Ricardo engine, ৳764,500 from EVOL, ৳825,000 with a Cummins engine and ৳1,155,000 with a Perkins engine.

What size generator does a six-storey building need?

It depends mostly on the lift and pumps. Many six-storey buildings with one lift and two pumps need 40 to 62.5kVA. A proper load calculation, including the lift’s starting current, is the only way to be sure.

Is Cummins better than Ricardo?

Cummins engines are generally built for heavier and more frequent use and cost more. Ricardo-engine sets are good value for standby use of a few hours a week. Choose based on how many hours the generator will actually run.

How many kW is 100kVA?

About 80kW, using the standard 0.8 power factor for diesel generators.

Do I need a canopy?

If the generator will sit outdoors or near people, yes. A canopy protects it from weather and cuts noise. Open sets need a dedicated, ventilated generator room.

How long can a generator run continuously?

That depends on the engine’s rating. Standby-rated sets are meant for outages, not continuous duty. If you need many hours a day, tell us so we recommend an engine rated for prime power.

How often should a standby generator be serviced?

Run it weekly for a short test, and have a full service at least once a year or at the running-hour interval in the engine manual, commonly 250 hours, whichever comes first.

Do you deliver and install generators outside Dhaka?

Yes, we deliver across Bangladesh and can arrange installation. Call +880 1712-567878 to discuss your site.

Choosing your generator

Price follows engine brand and size, but the right generator starts with your load and how often it will run. Send us your list of loads, especially lifts and pumps, and we will recommend the size, brand and ATS that suit your building and budget. Call +880 1712-567878 or message us on WhatsApp.

Frequently asked questions

What is the price of a 30kVA generator in Bangladesh?

In our range a 30kVA canopy generator costs ৳360,000 with a Ricardo engine, ৳695,000 from EVOL, ৳750,000 with a Cummins engine and ৳1,050,000 with a Perkins engine.

What size generator does a six-storey building need?

It depends mostly on the lift and pumps. Many six-storey buildings with one lift and two pumps need 40 to 62.5kVA. A proper load calculation, including the lift's starting current, is the only way to be sure.

Is Cummins better than Ricardo?

Cummins engines are generally built for heavier and more frequent use and cost more. Ricardo-engine sets are good value for standby use of a few hours a week. Choose based on how many hours the generator will actually run.

How many kW is 100kVA?

About 80kW, using the standard 0.8 power factor for diesel generators.

Do I need a canopy?

If the generator will sit outdoors or near people, yes. A canopy protects it from weather and cuts noise. Open sets need a dedicated, ventilated generator room.

How long can a generator run continuously?

That depends on the engine's rating. Standby-rated sets are meant for outages, not continuous duty. If you need many hours a day, tell us so we recommend an engine rated for prime power.

How often should a standby generator be serviced?

Run it weekly for a short test, and have a full service at least once a year or at the running-hour interval in the engine manual, commonly 250 hours, whichever comes first.

Do you deliver and install generators outside Dhaka?

Yes, we deliver across Bangladesh and can arrange installation. Call +880 1712-567878 to discuss your site.

Related products

More buying guides

All guides →
Custom quotation · free site survey

Get a custom quotation

I need power for

No obligation. Our project team will call you to discuss the details.